RFID Tagging & Writing RFID Tag

ODM-Mobile: RFID Tagging (1)

Supplied RFID Specification:
    • HF / NFC 13.56 MHz Frequency
    • ATEX Zone 1 certified
    • Mounting: Support on Metal surface
    • Robust: IP 68 housing
    • Operation Temp: -40°C ... 85°C
    • Size / Colour: 34mm Round / Black
ODM uses RFID technology in locating and tracking the Tag ID more accurate and quicker than traditional Barcode label.
 
The proposed RFID Tag is rugged and ATEX Zone 1 certified, which is:
    1. Suitable to be used in outdoor and under hot temperature
    2. Safe to be used in hazardous environment (zone 1)
    3. Support mount on metal surface
    4. Maintenance free; is not battery powered and no routine cleaning is required
There are two ways of mounting such type of RFID tag, either:
    1. Mounting directly on a clean surface of the asset with cover of epoxy, or
    2. Cable tie

 

ODM-Mobile: RFID Tagging (2)

After the RFID tag is tagged to the location / equipment, user may procced to write the Tag ID on the toe RFID tag.
 
To write the Tag ID to the RFID Tag:
    1. Browse and look for the tag group (e.g. Go to “Ad-Hoc” task and select “Log Randomly”)
    2. Right slide on the tag of the tag group (usually is the 1st tag of the group, where user will start taking the data)
    3. Click on “Write RFID” icon
    4. When it is ready to write the RFID tag, place the BACK (centre) of mobile device on to the RFID tag
    5. Once the RFID tag is written successfully, the message “Tag Written” will be displayed

 

Article Details

Article ID:
27
Rating :